Miele DA 399-6 EXT 작동 및 설치 지침 - 페이지 27

{카테고리_이름} Miele DA 399-6 EXT에 대한 작동 및 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele DA 399-6 EXT 36 페이지. Cooker hood
Miele DA 399-6 EXT에 대해서도 마찬가지입니다: 사용 설명서 (36 페이지)

Miele DA 399-6 EXT 작동 및 설치 지침
a Extraction
b Recirculation
c Ventilation grille positioned at the top for recirculation
de (only d is required for recirculation mode cooker hoods): The shaded area
represents the wall or ceiling area for the vent cut-out, for fitting the
connection socket and on EXT models for feeding the connection cable
through to the external motor. Recirculation mode cooker hoods only require
and electrical connection socket.
Connection for air extraction  150 mm, or 125 mm with reducing collar.

Safety distance between hob and cooker hood

When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker
hood is as follows, unless a greater distance is specified by the manufacturer of
your cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance
Electric hob
Electric grill
Deep fat fryer (electric)
Multi-burner gas hob with a maximum total output of
12.6 kW, no burner exceeding 4.5 kW.
Multi-burner gas hob with a total output of more than
12.6 kW, or a multi-burner gas hob where one burner
exceeds 4.5 kW.
Single gas burner with a maximum output of 6 kW.
Single gas burner with output exceeding 6 kW.
Installation
Minimum distance S
450 mm
650 mm
650 mm
650 mm
760 mm
650 mm
760 mm
27