HP 3000 969KS/420 매뉴얼 - 페이지 14
{카테고리_이름} HP 3000 969KS/420에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HP 3000 969KS/420 20 페이지. 9x9 to k class conversion
•
If the computer is in a rackmount cabinet, a #15 and #25 TORX head driver are needed.
If the HP 9000 computer to be worked on is mounted in a rack, it may need to be removed for certain
procedures. Refer to the Cabinet Installation Guide part number A2375-90007, or the Computer
Cabinet Users Manual part number C2785-90001 for detailed procedures on removal of the
computer from the rackmount cabinet. The Service Manual also contains Removal and Replacement
procedures for the rackmount cabinet.
Modifying the Console, Primary and Alternate boot paths
The Console path is identical for the HP3000 and HP9000, However the Primary/Alternate boot
paths, UPS, LAN and Modem paths are different and must be modified. The following are the
default paths for the HP9000:
•
Console
10/4/0.0
•
Primary Boot
10/0.6
•
CDROM
10/12/5.2
•
DDS
10/12/5.0
The default values identified above may or may not apply to the customer's configuration. Using the
appropriate PDC commands, set the boot paths to the correct value.
Additionally, the following paths are different for the HP9000:
•
UPS
10/4/0.1
•
Modem
10/4/0.7
•
LAN
10/12/6
6
Conversion Procedures