4-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the front. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
4-2. Selecting A Location
Movement
!
Location
Special installation may be required where gasoline or volatile
liquids are present − see NEC Article 511 or CEC Section 20.
4-3. Connection Diagram
1
Ref. 803 822-A / Ref. 801 915-A
SECTION 4 − INSTALLATION
OR
1
18 in.
(460
mm)
2
3
12
10
9
11
Tipping
2
3
18 in.
(460
mm)
5
4
6
7
8
!
Do not move or operate
unit where it could tip.
!
Do not stack units. Beware of
tipping.
1
Lifting Forks
Use lifting forks to move unit.
Extend forks beyond opposite side
of unit.
2
Hand Cart
Use cart or similar device to move
unit.
3
Line Disconnect Device
Locate unit near correct input
power supply.
loc_2 3/96 -Ref. 803 822-A
.
The proper interface kit must
be installed in the welding pow-
er source/interface unit to allow
it to be connected to the robot.
1
Robot (Will Vary According To
Application)
2
Motor/Drive Assembly
3
Gas Cylinder
4
Gas Hose
5
Robot Control
6
Robot Input/Output Cable
7
Gas And Motor Control Cable
8
Welding Power
Source/Interface Unit
9
Negative (−) Weld Cable
10 Workpiece
11 Voltage Sensing Lead
(Optional)
.
Positive (+) voltage sensing
lead is contained in the motor
cable.
12 Positive (+) Weld Cable