5-2. Meter Functions

.
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Scratch
Start TIG
Lift-Arc Trigger Hold TIG
TIG
MIG
Pulsed
MIG
CC
Stick
V-Sense
Feeder

5-3. Mode Switch Settings

.
The Stick and CC modes provide the Adaptive Hot Start™ feature, which automatically increases the output amperage at the start of a weld should
the start require it. This eliminates electrode sticking at arc start.
Mode Switch Setting
Scratch Start TIG
Lift-Arc Trigger Hold TIG
TIG
MIG
Pulsed MIG
CC
Stick
V-Sense Feeder
Meter Reading At Idle
V
71.7
Actual Volts (OCV)
Preset Amps
V
Blank
Preset Amps
V
Blank
Preset Amps
V
24.5
Preset Volts
V
PPP
Pulse Display
Pulse Display
V
Blank
Preset Amps
V
71.7
Actual Volts (OCV)
Preset Amps
V
71.7
Flashes OCV And Preset
GTAW − See Section 5-4
GTAW With HF Unit, Pulsing Device, Or Remote Control
GMAW-P (Requires an external pulsing device.)
Stick (SMAW) With Remote On/Off
MIG (GMAW) With Voltage Sensing Wire Feeder
A
85
A
85
A
85
A
Blank
A
PPP
A
85
A
85
A
Blank
Process
GTAW
GMAW
SMAW
Meter Reading While Welding
V
A
10.3
85
Actual Volts
Actual Amps
V
A
10.3
85
Actual Volts
Actual Amps
V
A
10.3
85
Actual Volts
Actual Amps
V
A
24.5
250
Actual Volts
Actual Amps
V
A
24.5
250
Actual Volts
Actual Amps
V
A
24.5
85
Actual Volts
Actual Amps
V
A
24.5
85
Actual Volts
Actual Amps
V
A
24.5
250
Actual Volts
Actual Amps
Output On/Off Control
Electrode Hot
At Remote 14
At Remote 14
At Remote 14
At Remote 14
At Remote 14
Electrode Hot
Electrode Hot
OM-257 486 Page 21