aquantica at2i 운영 매뉴얼 - 페이지 10
{카테고리_이름} aquantica at2i에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. aquantica at2i 16 페이지. For the canon t2i
The Aquatica housing for the Canon T2i / 550D offer a large choice of connectors to take full advantages of all the various strobes strobes available on
the market today. Standard choice available are:
20066-NK:
Two Nikonos type manual connectors.
20066-OPT:
Two optical fiber connectors to accept two Sea & Sea elbow type cords or two straight type cord (INON).
20066-HYB
One Nikonos Manual connector and one Optical connector to accept either one Sea & Sea elbow type
cord or two staright standard optical cords.
20066-KM
One Ikelite manual type connector
Optional also are: S6 type connectors and available in the summer 2010, the Nikonos type 6 pins connectors
Depending on which strobe system you are using, you can mount the necessary shoes or brackets or Base Ball onto the threaded holes on the top of
the hand grips. Use of the Aquatica Technical Lighting Control Strobe Arm System is recommended.
There is also a 1/4"-20 threaded holes provided on the bottom of the housing that can be used for various mounting applications. For example, A mount-
ing tray could be fitted on the bottom of the housing. As well a 1/4"-20 threaded hole on top of the front half of the housing
will accept an Aquatica bracket or Base Ball that can hold a small focus light or a strobe arm.
FOR OPTICAL CONNECTORS
The housing with optical connectors are supplied with adapter for typical straight cord used by INON and other strobe
manufacturers, and angled Sea & Sea type cords, select the desired connection and install on the optical port base,
tighten the set screw into place with the supplied hexagonal wrench.
In order to to use Opticall triggering, the built-in flash of the camera need to be in the up position, this is done at time of
installation or by using the pop up button on the housing (key #11). at this stage it would be the right time to select the
proper sync mode that you want to use(rear, slow, etc.).
Note: it is advisable to turn the camera off when travelling to your dive site in order to avoid useless drain of the camera
and strobes the batteries. Field testing as shown that mixing different brands of strobes give unreliable result and should
be avoided. Also noteworthy is the fact that many strobe offer Optical triggering, but TTL is only available with thoses that offer S-TTL type of signal,
please check carefully with your dealer prior to purchasing your strobes to make sure that they are indeed able to provide true TTL exposure.
When using Optically triggered strobes do not to install the hot shoe on the camera (HYB version) as this hot shoe disengages the internal built-in flash
of the camera and prevent this later from triggering. Always do a few test exposures once you finished setting up the strobes to confirm that they are
functionning as expected
Internal switch board circuit:
Your Aquatica T2i / 550D Pro Digital housing might be supplied with two Nikonos type connectors which are in turn connected to a switch board circuit.
Optional Ikelite bulkheads connectors are also available.
When preparing the sync cord be sure to lubricate the O-ring on the sync cord's connector with a light coat of Aquatica O-ring lubricant, Also advisable is
to put a light coat of O-ring lubricant on the threads of this connector.
Your Canon Digital camera design does not allow flashes to be connected directly to the camera and be used in eTTL unless they are original Canon
flashes in third party housing with the required connector and cords.
On your housing you will find two bulkhead connectors, the main and secondary connectors are wired through a switch board that will allow you to even-
tualy evolves as underwater strobes technology does in the future. By default your housing is delivered with the switch board set to full manual, if eTTL
exposure is desired then it can be made in either of two methods:
1) By using a single flash from Canon or other brand (that is eTTL compatible with your camera) in a underwater
housing connected with a proper 6 pins TTL cord to a compatible 6 pins connectors on your Aquatica housing.
2) By using an external eTTL converter connected to a 6 pins connector on your Aquatica housing to which one or two
underwater strobes with compatible TTL cords are then connected to this converter, (check strobe and converter
manufacturer for compatibility).
Set up instruction for eTTL operation: Using the tip of a pen push the switches 1, 2, 3 & 4 to the ON (up) position,
this will activate the connections on your main 6 pins bulkhead connector allowing eTTL communication between the camera and the housed flash or
eTTL converter.
Set up instruction for manual operation: All switches must be in the OFF (lower) position, in this case all eTTL connections are disabled and only the
ground and sync are left active, this will allow two underwater strobes or housed flashes to be connected directly via the main and secondary bulkhead.
MOUNTING AND ATTACHING FLASHES
page 9