Miller WP-9 소유자 매뉴얼 - 페이지 15
{카테고리_이름} Miller WP-9에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller WP-9 28 페이지.
Miller WP-9에 대해서도 마찬가지입니다: 소유자 매뉴얼 (20 페이지)
SECTION 5 − MAINTENANCE & TROUBLESHOOTING
5-1. Routine Maintenance
n = Check
* To be done by Factory Authorized Service Agent
Daily
n Nozzle For Cracks − l If Necessary
Weekly
n
Collet For Wear −
l If Necessary
n Power Cable For Cracks,
Monthly
Wear − l If Necessary
*
When using a water-cooled torch, maintain cooling equipment according to the manufactures recommendations.
5-2. Troubleshooting
.
Before using troubleshooting table, check selection and preparation of tungsten electrode according to Section 6.
Trouble
Arc will not start. High frequency present
and visible at the torch.
Lack of high frequency; difficulty in es-
tablishing arc.
Torch gas valve not working properly (if
applicable).
No shielding gas flow from torch.
Z = Change
~ = Clean
n Collet Body Threads −
l If Necessary
n
Gas Hose For
Cracks, Leaks, Wear −
l If Necessary
n Power, Gas, And Water
Cable Connections To En-
sure They Are Tight
Check cable and work connections. Be sure weld circuit is complete (see Section 4-3).
Check and be sure shielding gas is present.
Select proper size and type tungsten. Properly prepare tungsten according to Section 6.
Check cables and torch for cracks or bad connections. Be sure that torch cables are not close to any
grounded metal. Repair or replace necessary parts.
Check torch consumables. Be sure collet and collet body are correctly installed and tightened (see Sec-
tion 4-1).
Check welding power source High Frequency control, and if necessary, check and adjust spark gaps.
Have Factory Authorized Service Station/Service Distributor check valve.
Be sure valves on gas supply are open.
Check cable for kinks or blockage.
Check and tighten all gas supply fittings.
Check cables and torch for cracked insulation or bad connections. Repair or replace (see Section 5-1).
!
Disconnect torch before maintaining.
l = Replace
n Check Tungsten Preparation (See Section 6)
n Gas Lens Screen −
l If Necessary
*
n
Water Hose, If Applic-
able, For Cracks, Leaks,
Wear − l If Necessary
n
Cable Cover For
Tears, Holes, Or Wear −
l If Necessary
Remedy
n Gas Valve, If Applicable −
l If Necessary
n
Back Cap O-Ring −
l If Necessary
OM-225 430 Page 11