Important points about the air-motor:
1. Maximum pressure of compressed air: 0.6Mpa.
2. Use only clean compressed air (with no dust, no water etc).
3. Use hoses and valves in sizes allowing proper liquid flow.
4. Use an air filter/lubricator to maintain proper operation of
the air-driven motor.
5. Regulate motor lubrication to approx. 1 drop per minute.
Remember to use an air filter & lubricator.
Recommended (available separately)
Air Filter: CKD Brand, model F-1000-8-W
Lubricator: CKD Brand, model L-1000-8-W
MAINTENANCE
⚫ Always make sure that the pressure, delivery rate, vibration rate and
noise do not exceed their standard permitted level. If any of them does,
stop the device and take appropriate measures to find the reason of
malfunction.
⚫ After every 300 hours of operation, re-grease the device through the
P7-55 grease nipple after removing the P7-9 case cap. Remember to
remove the accumulated oil particles first.