aquatherm AT550 설치 매뉴얼 - 페이지 9

{카테고리_이름} aquatherm AT550에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. aquatherm AT550 14 페이지. Swimming pool & spa heat pumps w/titanium heat exchanger

E. ELECTRICAL CONNECTIONS AND WIRING
size wire from power supply to the unit's main contactor located on the right side of high
voltage compartment. The ground wire connection is located on the base of the box to the
left of the contactor. A knock out is located on the bottom of the box just below the contactor.
A sealtight fitting must be used to attach the conduit to the electric box. All other models
require minimum #8 copper stranded wire. Model AT 1200 requires #6 wire.
• Replace electric box high voltage cover.
• Replace plastic front panel and place conduit and plastic adaptor in slot provided on right
side of unit.
• Run a #8 solid copper
wire from the bond lug
located on the right
side of unit to pool
pump bond wire or a
7 ft. copper rod driven
into the ground.
• Turn power to unit and
timeclock on.
8
POWER
SUPPLY
SEALTITE
BUSHING