Thank you for purchasing an Aquatic Life Deionization System. When properly maintained, this unit
will provide you with years of high quality, low TDS filtered water. Contact us with any questions or if
you are missing or need replacement parts at 888-548-3480, or customersupport@aquatic life.com
WARNING: Please read carefully before proceeding with installation. Your failure to follow any attached
instructions and operating parameters may lead to the product's failure and possible property damage.
OVERVIEW
Water quality is often measured by the amount of Total Dissolved Solids (TDS) in the water. After water
is filtered by an RO Membrane (not included), there is usually a small amount of TDS left in the water. In
certain non-drinking water applications, it is important to remove the remaining TDS from the water.
This is accomplished by filtering the water through a resin that is charged with Cation and Anion resins
(H+ and OH-). As the resin absorbs the TDS, it will change color. When the entire resin has changed
color, it is time to replace the DI Cartridge. NOTE: Filter Cartridges and Membrane life may vary based
on local water conditions and amount of use.
Contents:
2.5" x 10" Canister Housing
Mounting Bracket
Mounting Screw Set
DI Color Changing Resin Cartridge
Blue Tubing 1/4"
Press 1/4" x MPT 1/4" Elbow w/Blue Clip
Press 1/4" x MPT 1/4" w/Blue Clip
Plumber's Tape
Canister Wrench
Dual TDS Meter
OPERATING GUIDELINES
DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the unit.
The maximum incoming water pressure for the unit is 80 PSI. If the pressure is more than 80 PSI, a
pressure regulator is required.
Reverse Osmosis filtered water should not be run through a copper tube. The pure RO/DI water can
leach copper from the pipe, eventually leading to holes in the pipe.
DO NOT operate the unit unattended.
540500
540501
540502
Single
Dual
Single
Canister
Canister
Canister
1
2
1
1
1
1
1
2
1
1
2
2
2
2
1
1
1
1
na
na
540503
Dual
Canister
1
2
1
1
1
1
1
2
1
1
2
2
2
2
1
1
1
1
1
1