Axor Uno Kitchen Faucet with Sidespray 14856001 설치 지침 / 보증 - 페이지 6
{카테고리_이름} Axor Uno Kitchen Faucet with Sidespray 14856001에 대한 설치 지침 / 보증을 온라인으로 검색하거나 PDF를 다운로드하세요. Axor Uno Kitchen Faucet with Sidespray 14856001 12 페이지. Axor - hansgrohe, inc. faucet installation instructions / warranty
Re-set the High Temperature Limit Stop (optional)
Close the drain OR cover it with a wash cloth.
Use the included 4 mm Allen wrench to push the
screw cover into the handle. Retrieve the screw
cover when the handle is removed.
Use the 4mm Allen wrench to loosen the handle
screw 4 complete revolutions. Remove the
handle and put it in a safe place.
Remove the decorative nut cover and put it in a
safe place.
Remove the handle screw from the stem of the
cartridge. Remove the high temperature limit
stop.
Replace the high temperature limit stop so that
the pin on the cartridge is in the desired slot on
the limit stop. Note: the temperatures given in
the diagram assume a water heater temperature
of 140
F, a cold water temperature of 50
F
o
o
and a water pressure of 45 PSI.
Replace the decorative nut cover. Replace the handle screw. Use the Allen wrench to turn the
screw 4 revolutions.
Replace the handle. Finish tightening the handle screw. Turn on the water and test the faucet.
6