Re-set the high temperature limit stop (optional)
This step should be taken if the faucet is to be used by small
children or others who should be protected from scalding.
Pull out the screw cover, located on the
•
bottom of the handle.
Use a 3 mm allen wrench to loosen the
•
set screw 2 complete turns.
Pull off the nut cover and the green high temperature limit stop ring.
•
Reinstall the high temperature limit stop ring so that the black positioning pin
•
is in the notch corresponding to the desired high temperature. The
temperatures shown in the diagram assume an incoming cold water
temperature of 50
Center and replace the nut cover.
•
Replace the handle.
•
Tighten the set screw.
•
4
F and an incoming hot water temperature of 140
o
.
o