Axxent ISV 1090 사용자 설명서 - 페이지 9

{카테고리_이름} Axxent ISV 1090에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Axxent ISV 1090 10 페이지. Universal induction loop amplifier

THE CONTROLS (Front)
MIC 1, MIC 2
Left on the front side you will note four control knobs. The
two left ones control the microphone input level. On the rear
you will find the two corresponding 3pin XLR connectors. As
already described on the previous pages, the input sensitivity
of these inputs may be altered via small internal potentiome-
ters, located on the printed circuitry board. Phantom power
(48 V) for condenser microphones can be activated separate-
ly for each input via DIP switches labelled „PHAN 2 1" (lower
ON position).
LINE 1, LINE 2
Right from the MIC potentiometers you will note two control
knobs for the line signals. The corresponding connectors are
also located on the rear side. Line 1 is a balanced 3pin XLR
connector (female), while LINE2 is equipped with a 4 pole
Phoenix connector. A+/A- and GND is the balanced line input,
while V+ with GND represents the 22 v DC output, intended
as power supply for external microphone preamplifiers.
DRIVE, DRIVE CURRENT
The DRIVE control sets the output power (output current) of
the amplifier indicated by the LED chain. The "normal" safe
level is represented by the green LEDs, while the red LEDs
should only be lit at absolute level peaks.
HEADPHONE SYMBOL
This is the input connector for any type of headphones with
standard phone plug 3.5 mm in order to check the audio
signal for distortion or other anomalies.
axxent e.K. · Technologiezentrum Herzbachtal · Zum Wartturm 15 · 63571 Gelnhausen
fon: +49-6051-9165584 · fax: 9165585 · [email protected] · www.axxent.de
®
ISV 1090 Universal Induction Loop Amplifier
COMPRESSION
In the centre of the front side you see an LED chain, label-
led COMPRESSION. The bargraph indicates the amount of
compression, e.g. how much the dynamic range between the
lowest audible signal and the maximum peak levels are com-
pressed. This compression facilitates intelligibility especially
for the "quiet" low level signals, highly appreciated by hearing
impaired persons.
METAL
This potentiometer allows compensation of frequency ano-
malies, caused by metal parts or tubes located in vicinity of
the induction loop. In order to determine these frequency
response anomalies, we recommend the use of an induction
loop measurement instrument.
TEMP
The red TEMP LED lights when the maximum operating tem-
perature is exceeded. If it lights up continuously, the induction
loop is probably not properly sized or the amplifier is overdri-
ven. Please check out these potential trouble causing sources.
POWER
Green LED indicator confirms activated POWER switch on
the right (ON).
User Manual