ARCCAPTAIN CUT50 사용자 설명서 - 페이지 19
{카테고리_이름} ARCCAPTAIN CUT50에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ARCCAPTAIN CUT50 20 페이지. Plasma cutter 50a
Keep it dry
Avoid rain, water and vapor infiltrating the machine. If there is, dry it
and check the insulation of the cutting machine (including that
between the connections and that between the connection and the
enclosure) with an ohmmeter. Only when there are no abnormal
phenomena anymore, can the machine be used.
Put the machine into the original packing in dry location if it is not to be
used for a long time.
Pay attention to maintenance
Periodic check should be carried out to ensure the long-term normal
use of the machine. Be careful when doing the periodic check,
including the inspection and cleaning of the machine interior.
Generally, periodic check should be carried out every 6 months, and it
should be carried out every 3 months if the cutting environment is
dusty or with heavy oily smoke.
Beware of corrosion
Please clean the plastic parts with neutral detergent.
6. TROUBLESHOOTING
Troubleshooting
The abnormity indicator on the front panel would illuminate in case of any failures inside
the cutting machine.
Malfunction phenomena
Turn on the machine, the LED screen
illuminates, the control PCB keys do
not function, and there is no response
when pushing the torch trigger.
Turn on the machine, the LED screen
illuminates, the control PCB keys work
normally, but there is no response
when pushing the torch trigger.
Turn on the machine, the LED screen
illuminates, and the fan works. When
pushing the torch trigger, the solenoid
valve functions, but there is no HF
discharge rustling.
Arc can not be ignited.
Digital Welder Expert, Know You More
The cutting machine crashes: Shut down the
machine, and restart it.
1) The LED4 on the main board is on: The
control PCB is damaged.
2) The LED4 on the main board is off: Check
the torch trigger and torch trigger wire.
The arc ignition part fails:
1) The interelectrode distance of the discharge
nozzle is too long.
2) There is leakage of the HF capacitor
222/15KV.
3) The mosfet or the optocoupler on the HF
board is damaged.
4) The input voltage is too low.
The air pressure is overly high or overly low.
16
Cause and solution
https://www.arccaptain.com