Architectural Area Lighting LC5 설치 지침 매뉴얼 - 페이지 3

{카테고리_이름} Architectural Area Lighting LC5에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Architectural Area Lighting LC5 16 페이지.

INSTALLATION INSTRUCTIONS
6.00"
3.25"
1.079"
A
8.50"
3.03"
5.375"
2.046"
3.75"
BALLAST HOUSING MOUNTING
DETAIL ORIENTATION
MOUNTING SURFACE
SEE NOTE #4 & #12 THRU #15
WIRE CONNECTORS
(BY OTHERS)
J-BOX (BY OTHERS)
16555 East Gale Avenue
City of Industry, CA 91745
(626)968-5666
WALL MOUNT STRAIGHT ARMS
FIXTURE INSTALLATION
O
(4)
0.531"
1) DRILL BOLT HOLES AND WIREWAY IN ACCORD TO
THE SUPPLIED MOUNTING TEMPLATE.
2) TURN OFF POWER.
3.54"
A
3) ADJUST FIXTURE HEAD TO THE DESIRE POSITION
AND SECURE WITH (2) BUTTON HEAD SCREWS.
4) LOOSEN BOTH SCREWS LOCATED BELOW BALLAST HOUSING.
WIREWAY
ALLOW DOOR TO HANG DOWNWARD. DISCONNECT WIRE
HARNESS BETWEEN BALLAST AND FLEXIBLE CONDUIT.
REMOVE BALLAST TRAY.
1.03"
A
5) SECURE BALLAST HOUSING TO MOUNTING SURFACE
WITH APPROPRIATE HARDWARE (SUPPLIED BY OTHERS).
6) RE-INSTALL BALLAST TRAY AND CONNECT WIRE HARNESS.
7) MAKE WIRE CONNECTIONS FROM BALLAST HOUSING
TO INCOMING LINES FROM WALL. (NOTE: ASSEMBLY MUST BE
GROUNDED TO INCOMING EQUIPMENT GROUND SUPPLY).
8) SECURE DOOR TO HOUSING BY TIGHTENING BOTH SCREWS.
9) APPLY CONTINUOUS BEAD OF SILICONE SEALANT ALL
AROUND BALLAST HOUSING AND MOUNTING SURFACE.
(SILICONE SUPPLIED BY OTHERS).
LAMP INSTALLATION
10) TO INSTALL LAMP, INSERT FINGERS INTO SLOTS
AND PULL BOTH LATCHES BACK SIMULTANEOUSLY.
11) OPEN THE BOTTOM HALF HOUSING AND INSTALL PROPER
LAMP (BY OTHERS). CLOSE BOTTOM HALF HOUSING, MAKE
SURE THE LATCHES SNAP BACK TO ITS ORIGINAL POSITION.
(2) BUTTON
HEAD SCREWS
BOLTS & WASHERS
SUPPLIED BY OTHERS
SERVICING BALLAST
12) DISCONNECT ALL POWER .
13) LOOSEN BOTH SCREWS LOCATED BELOW BALLAST
HOUSING. ALLOW DOOR TO HANG DOWNWARD.
14) SERVICE BALLAST AS NEEDED.
15) CLOSE BALLAST TRAY AND SECURE ON THE
HOUSING WITH (2) SCREWS.
CATALOG NUMBER
WVSS / WSS / WLS
FIXTURE HEAD
SEE NOTE #10 & #11
DATE
APPRVD
PART NO.
DATE
REV.
04/14/2008
A
A96266