Siemens Sitrans LVL200 사용 설명서 - 페이지 7
{카테고리_이름} Siemens Sitrans LVL200에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Siemens Sitrans LVL200 16 페이지. Vibrating switches
Installation procedure
7ML19985LS31
4
Mounting
4.1
Mounting instructions
If the electronics module is defective, it can be replaced by the user.
In Ex applications, only instruments and electronics modules with ap-
propriate Ex approval may be used.
4.2
Mounting preparations
In general, the electronics module can be also exchanged within the
type series against an electronics with another signal output (e.g.
relay against transistor output).
If you want to use an electronics module with a different signal output,
you can download the corresponding operating instructions manual
from our homepage under Downloads.
4.3
Installation procedure
To exchange the electronics module, proceed as follows:
1. Switch off power supply
2. Unscrew the housing lid
3. Lift the opening levers of the terminals with a screwdriver
4. Pull the connection cables out of the terminals
5. Loosen the two screws with a screw driver (Torx size T10 or slot
4)
Fig. 1: Loosen the holding screws
1
Electronics module
2
Screws (2 pcs.)
6. Pull out the old electronics module
7. Compare the new electronics module with the old one. The type
label of the electronics module must correspond to that of the old
electronics module. This applies particularly to instruments used
in hazardous areas.
8. Compare the settings of the two electronics modules. Set the
adjustment elements of the new electronics module to the same
setting of the old one.
Electronics module - Operating Instructions
1
2
7