Reading head installation...
Reading head
mounting holes (2)
•
Adjust the bracket so that the reading head
mounting holes align with the reading head casting.
Secure the bracket in place.
*8-32 x 3/4" SHCS (2)
A gap will exist between
bracket and reading head.
•
Insert the two *8-32 x 5/8" SHCS. Insure the bracket
is adjusted to provide proper screw head clearance.
Do Not Tighten Screws at this time.
•
Set each leveling set screw by placing a .001" - .003"
feeler gage between the set screw and the bracket.
•
Adjust each set screw until a slight drag is felt on the
feeler gage.
•
Evenly tighten the two 8-32 SHCS.
P.N. 385072-214 Ed C 11/05
Leveling set screws (3)
Installation Manual 385072-41
Encoder Installation Manual For: Bpt. Vert. Knee Milll
Cross Feed Y Axis - Right hand side
Alignment bracket removal ...
Slide brackets back
away from the
reading head and
cable
•
Use allen wrench from set screw adjustment to slide
alignment brackets away from the reading head.
•
Remove alignment brackets and save for possible
future use.
•
Move the axis through its full travel. Confirm that
the assembly does not interfere with the machine
movement.
•
With the longitudinal axis installation complete,
route the cables providing sufficient slack loops for
machine movement to the readout.
•
Secure cables by fastening with clips or ties.
•
Attach the linear encoder connectors to the readout.
•
Complete the installation by following the steps in
"Checking Your Installation" section in the encoder
"Reference Manual".