Table 9.
RAID
level
00
10
50
60
To create a RAID volume based on multiple drive groups (RAID 00, 10, 50, or 60), follow the steps presented here.
Step 1: Log in to Cisco IMC.
Step 2: Open the Storage tab and click on the Controller Info tab. Select the Create Virtual Drive from Unused
Physical Drives option; then proceed with virtual drive creation.
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public.
RAID 00, 10, 50, and 60 Configuration
Description
Configure RAID 00 by spanning two contiguous RAID 0 virtual drives, up to the maximum number of supported devices for the
controller
Configure RAID 10 by spanning two contiguous RAID 1 virtual drives, up to maximum number of supported devices for the
controller RAID 10 supports a maximum of eight spans. You must use an even number of drives in each RAID virtual drive in the
span. The RAID 1 virtual drives must have the same stripe size.
Configure RAID 50 by spanning two contiguous RAID 5 virtual drives. The RAID 5 virtual drives must have the same stripe size.
Configure RAID 60 by spanning two contiguous RAID 6 virtual drives.