Installation Instructions
RSX LED
8. Reorient luminaire to desired position on the tenon and Insert provided 7/16"-14 x 4-1/2" bolt through Mast Arm Mount
and drilled 1/2" Ø hole on tenon and place provided 7/16" nut onto bolt (see figure 12) and tighten securely to 45-50 ft-lbs.
9. Evenly tighten the Six (6) 3/8-16 UNC Mast Arm Set Bolts while maintaining the correct position of the luminaire to 23-27
ft-lbs.
10. Energize the luminaire to verify its operation and proper illumination of area.
WARNING: USE AND PROPERLY TIGHTEN THRU-BOLT AND NUT. FAILURE TO CORRECTLY INSTALL COULD RESULT IN SERIOUS
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
INJURY OR PROPERTY DAMAGE
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19