Concerning Operation

PROBLEM
Is the plug connect-ed
to electric outlet?
Is Fuse opended?
THE INDICA-
Is the condition of
TOR
power button good?
LAMPS(L.E.D)
DO NOT LIGHT
UP WHEN THE
Is the connector of the
POWER BUT-
P.C.B. ASS'Y connect-
TON IS
ed properly?
PRESSED.
Is input voltage of the
transformer normal?
Do you press
START/HOLD button?
PROGRESS
LAMPS(LED)
DO NOT LIGHT
UP.
MOTOR
Does the pressure switch
ROTATES
operate normally?
WHEN
START/HOLD
BUTTON IS
Check the output voltage
NOT
of P.C.B ASS'Y
PRESSED.
Is the strange noise gen-
erated when the pulsator
ABNORMAL
rotates in TEST MODE
NOISE DUR-
of P.C.B ASS'Y?
ING WASH
PROCESS.
Is the V-belt worn out?
28
TROUBLE SHOOTING
CHECK POINT
YES
NO
NO
YES
NO
YES
NO
YES
NO
YES
YES
NO
YES
CAUSE
NO
YES
Power button is defective
Improper connection of
the connector.
Transformer is defective
P.C.B. ASS'Y is defec-
tive.
NO
P.C.B ASS'Y is defective.
Pressure switch is defec-
tive.
Abnormal
P.C.B ASS'Y is defective
There is foreign matter
between pulsator and
tub.
V-belt is defective.
SOLUTION
Connect the plug.
Change Fuse
Change P.C.B ASS'Y.
Connect the connector
properly.
Change the transformer.
Change P.C.B ASS'Y.
Press START/HOLD but-
ton.
Replace P.C.B ASS'Y.
Change the pressure
switch.
Change P.C.B ASS'Y.
Remove the foreign mat-
ter.
Change the V-belt.