Whirlpool UXD8636DYS 설치 지침 및 사용 및 관리 매뉴얼 - 페이지 8

{카테고리_이름} Whirlpool UXD8636DYS에 대한 설치 지침 및 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool UXD8636DYS 36 페이지. 30 76.2 cm and 36 91.4 cm retractable pop-up downdraft vent system
Whirlpool UXD8636DYS에 대해서도 마찬가지입니다: 설치 사용 및 관리 지침 (40 페이지)

Whirlpool UXD8636DYS 설치 지침 및 사용 및 관리 매뉴얼
Determine which venting method is best for your application.
Vent system can terminate either through the wall or floor.
Island Location
Front (Standard)-Mounted
Blower Motor
A. Down vent
NOTE: For island locations, a front- or rear-mounted blower
motor can also be mounted for right or left venting if needed for
your application. Most island applications would still require the
venting to be directed down through the floor.
Built-In Cabinet Locations
A
B
A. Down vent
B. Left vent
C. Right vent
8

INSTALLATION INSTRUCTIONS

Venting Methods

Rear-Mounted Blower Motor
A
Island Location—Vent System Installed Under a Concrete
Slab Using PVC Sewer Pipe
Front (Standard) Mounted Blower Motor
A
M
L
A
Rear Mounted Blower Motor
A
M
L
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round metal vent transition with damper (supplied)
F. 6" (15.2 cm) round PVC coupling
G. Concrete slab
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90° PVC sewer pipe elbow
J. Tightly pack gravel or sand completely around pipe.
K. 6" (15.2 cm) round 90° PVC sewer pipe elbow
L. 6" (15.2 cm) round PVC coupling
M. 12" (30.5 cm) minimum
Calculating Vent System Length
C
3¼" x 10" (8.3 x 25.4 cm) rectangular vent is required from the
blower motor box. It can be transitioned to 6" (15.2 cm) round
vent if needed.
Maximum Length of Vent System
Vent
6" (15.2 cm) round
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
B
D
C
K
J
B
D
C
K
J
Length
35 ft (8.9 m)
35 ft (8.9 m)
E
F
G
H
I
E
F
G
H
I