RANGE HOOD INSTALLATION INSTRUCTIONS
For questions about features, operation/performance, parts, accessories, or service, call: 1-800-253-1301.
Residential range hoods can be installed to comply with Sections 308 and 309 of ADA Guidelines when used with appropriately
mounted controls installed at 15" (38.1 cm) to 40" (101.6 cm) above the floor, and control access should not require reaching over
a cooking appliance.
The following range hoods can work in an ADA-compliant situation when the range hood is wired to operate from a dedicated
standard electrical wall switch. To facilitate this application, share the information on the following pages with your electrician
when preparing for the installation.
NOTE: All the models can be controlled only by one remote switch. The switch activates or deactivates the motor and the light
of the hood.
Two-Speed Range Hoods
(with rocker switch)
UXT20
■
UXT30
■
UXT40
■
UXT41
■
Tools and Parts
Tools Needed
Wire stripper
Parts Needed
UL Listed/CSA
UL Listed/CSA
Approved wire
connectors
UL Listed single pole
toggle light switch
W11108368A
FOR ADA COMPLIANCE
In Canada, for assistance, installation, and service, call: 1-800-607-6777.
UXT42
■
INSTALLATION REQUIREMENTS
#2 Phillips
Flat-blade
screwdriver
screwdriver
UL Listed #14
Approved
(minimum)
1/2" (13 mm)
3 wire cable
strain relief
UL Listed deep
single-gang
switch box
Intermediate Range Hoods
(with rotary switch)
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
(latest edition), or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local
codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
A 120-volt, 60 Hz., AC-only, 15-amp fused electrical circuit
■
is required.
Three-Speed Range Hoods
(with push buttons)
UXT52
■
WVU37U
■
Electrical Requirements
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575