Xerox N24/32/40 Technical Instructions
Photo 43
Photo 44
Photo 45
Photo 46
Photo 47
Step 39
With the seal pull tab through the seal
exit port, use needle nose pliers to hold
the agitator bar in the correct position
while reinstalling the seal exit port plug.
(See Photo 43) Pull the seal pull-tab tight
so the agitator bar does not hit the
pull-tab.
Step 40
Reinstall the contact end cap on the
toner hopper. Using a Philips screwdriver
install the screw that hold the end cap.
(See Photo 44)
Step 41
Push the fill plug out of the toner
hopper. (See Photo 45)
Step 42
Place the cover of the toner hopper onto
the hopper. Push down on the cover
making sure all five clips a securely
fastened. Install the four screws to the
top of the cover. (See Photo 46)
Step 43
Reinstall the doctor blade and the two
screws that hold the blade in place.
(See Photo 47)
Step 44
Place the mag roller bushing
and the bearing onto the mag
roller. Reinstall the roller back
into the hopper. Slide the stabi-
lizing bushing, the drive gear
and the end cap back onto the
end of the mag roller. Reinstall
the screw that holds the end
cap onto the hopper.
(See Photo 48)
Photo 48
Step 45
Fill the toner hopper with the
correct fill load of toner.
(See Photo 49) Reinstall the fill
plug.
Photo 49