Warning:
Under no circumstances is this heater to be installed in a makeshift or "temporary" manner.
It may be fi red only after the stove is installed properly.
DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR DISTRIBUTION
DUCT.
We recommend that our woodburning hearth products be installed and serviced by
professionals who are certifi ed in the U.S. by the National Fireplace Institute
NFI woodburning Specialists or who are certifi ed in Canada by Wood Energy
Technical Training (WETT).
Outside combustion air or fresh air into the room may be required in your area, consult
local building codes (see Combustion Air section).
Clearances – Residential
1.
This heater may be installed using a single-wall connector (smoke pipe) or listed double-
wall connector (see Mobile Home installation).
2. Clearances to combustible surfaces and materials using single-wall connector are shown
in Figure #2.
Clearances may be reduced with various heat insulating materials. Consult local fi re
codes and authorities for approval.
3. Alternately, for close clearances, use a listed double-wall connector.
See Figure #2a.
Fig #2
SINGLE WALL
CONNECTOR
Fig #2a
DOUBLE WALL
CONNECTOR
Minimum Clearances to Combustibles – Residential
12"
22"
18"
30"
5"
15"
14"
26"
ALCOVE:
6
Do not connect this unit
®
(NFI) as
to a chimney fl ue serving
another appliance.
11"
10"
20"
16"
16"
28"
Min. Height 7 1/2 feet
Max. Depth 4 feet
11"
25"
4"
18"
4"
020512-20 ALT5