3Com SSII ADVANCED RPS POWER MODULE TYPE 3 설치 매뉴얼 - 페이지 9

{카테고리_이름} 3Com SSII ADVANCED RPS POWER MODULE TYPE 3에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. 3Com SSII ADVANCED RPS POWER MODULE TYPE 3 12 페이지. Superstack 3 advanced rps type 3 power module
3Com SSII ADVANCED RPS POWER MODULE TYPE 3에 대해서도 마찬가지입니다: 중요 정보 (1 페이지)

CAUTION: Wenn sich das Type 3 Power Module im Advanced RPS
Chassis befindet kann es zu einer Energiegefahr am DC Stecker
kommen.

Installing the Power Module

CAUTION: Never plug a hot power module into the Advanced RPS.
You may damage the power module. Allow sufficient time
(approximately 1 minute) for the module to cool down before
inserting it into the power module slot.
CAUTION: It is important that the power modules are cooled
effectively. We strongly recommend installing the power modules as
evenly as possible between the top and bottom slots. Refer to Table 1
for recommendations on slot configurations for the Type 3 Module.
You can "hot-insert" the Type 3 Module into the chassis, that is, you
do not need to remove mains power from the chassis before you
insert a power module.
1 Take off the blanking plate by removing the fixing screw. Keep the
blanking plate and screw in a safe place. If you remove the module at
any time, you must replace the blanking plate to maintain the flow of
cooling air within the chassis.
2 Hold the power module so that the text on the front panel is upright,
and insert it into the chassis, sliding the module into the runners.
Push firmly to ensure the connectors are fully engaged.
3 Secure the module with the screws provided using a suitable tool.
CAUTION: When removing a power module that has just been
operating, beware of hot components.
CAUTION: Do not operate the Advanced RPS continuously with any
of the rear slots open. This will disturb the flow of cooling air and
reduce the life of your unit.
Installing the Power Module
9