Aleko LOCKMASTER L110C 매뉴얼 - 페이지 11

{카테고리_이름} Aleko LOCKMASTER L110C에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aleko LOCKMASTER L110C 17 페이지.

Aleko LOCKMASTER L110C 매뉴얼
Setting of
the Control
Board
1. DIP Switches
The DIP switches are
used to set the limit
switch of the opener to
be NO or NC, auto close
time of the gate opener
and fast change the
open/close direction
which is determined by
the position of the gate
opener installed.
DIP Switch #1
DIP Switch #1:ON – NO / OFF –NC
This mode enables user to set the board to work with motor with NC or NO limit switch
NOTE: Factory default setting is NO
DIP Switch #2–#4: Auto close time of the gate opener
DIP Switch #2: ON – 12.5 Seconds OFF – 0 Seconds
DIP Switch #3: ON – 25 Seconds OFF – 0 Seconds
DIP Switch #4: ON – 45 Seconds OFF – 0 Seconds
NOTE: The auto-close function would be disabled if all 3 dip switches are turned to off (factory default
setting).
Setting of the Control Board
Limit switch NC (
:
) or NO (
normally closed
10
)
normally open