Alemite 7730 서비스 매뉴얼 - 페이지 13
{카테고리_이름} Alemite 7730에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alemite 7730 14 페이지. High-pressure bulk grease pump
High-Pressure Bulk Grease Pump
Installation
These pumps connect to a female camlock which is
part of a bulk container system. See Figure 6 for a typical
installation.
Additional items that should be incorporated into the
air piping systems are listed in Table 5.
Part Number
5612-2
Moisture Separator
SM7612-B
Regulator and Gauge
5912-2
Lubricator *
Table 5 Air Line Components
* Although the air motor is lubricated at the factory,
the life of the motor can be extended with the use of a
lubricator.
Figure 6 Medium-Pressure Grease Pump Model 7730 (Shown with Accessories) - Typical Installation
Alemite Corporation
Description
Prove the Pump
Aerated product is due to external leakage; either at the
pump or at the connection fittings on the bulk container.
Isolation of the pump from the bulk container can help
"prove the pump".
1. Place the pump in oil.
2. Follow procedures 9 through 13 within the section
entitled Bench Test.
If the pump does not leak externally * the fittings on
the bulk container may not be sealing properly.
* The pump may still contain an air leak at
O-Rings (11) and/or (24). Refer to the Troubleshooting
Chart for details.
13
SER 7730
Revision (8-01)