ARO 66610*-*-C series 운영자 매뉴얼 - 페이지 8
{카테고리_이름} ARO 66610*-*-C series에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ARO 66610*-*-C series 8 페이지. 1” diaphragm pump
ARO 66610*-*-C series에 대해서도 마찬가지입니다: 운영자 매뉴얼 (8 페이지), 운영자 매뉴얼 (13 페이지)
Product discharged from exhaust outlet.
S
Check for diaphragm rupture.
S
Check tightness of (14) diaphragm screw.
Air bubbles in product discharge.
S
Check connections of suction plumbing.
S
Check "O" rings between intake manifold and fluid caps.
S
Check tightness of (14) diaphragm screw.
8"
12-1/2"
(318 mm)
6-1/4"
(159 mm)
7-5/16"
Page 8 of 8
TROUBLE SHOOTING
DIMENSIONAL DATA
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).
1 - 11-1/2 N.P.T.F. - 1
Rp 1 (1 - 11 BSP parallel)
(203 mm)
1-1/4"
(32 mm)
(186 mm)
1 - 11-1/2 N.P.T.F. - 1
Rp 1 (1 - 11 BSP parallel)
Low output volume, erratic flow, or no flow.
S
Check air supply.
S
Check for plugged outlet hose.
S
Check for kinked (restrictive) outlet material hose.
S
Check for kinked (restrictive) or collapsed inlet material hose.
S
Check for pump cavitation -- suction pipe should be sized at least as
large as the inlet thread diameter of the pump for proper flow if high
viscosity fluids are being pumped. Suction hose must be a non-col-
lapsing type, capable of pulling a high vacuum.
S
Check all joints on the inlet manifolds and suction connections.
These must be air tight.
S
Inspect the pump for solid objects lodged in the diaphragm chamber
or the seat area.
(66610X, 66611X)
(66612X, 66613X)
11-9/16"
(294 mm)
4"
13/32" Slot
(66610X, 66611X)
(66612X, 66613X)
Figure 5
8-9/16"
(217.5 mm)
Outlet
6-1/2"
(165 mm)
Inlet
(102 mm)
(10 mm)
Air Inlet
1/4 - 18 N.P.T.F. - 1
PN 97999-100