ARO PE03P A0S Series 운영자 매뉴얼 - 페이지 3
{카테고리_이름} ARO PE03P A0S Series에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ARO PE03P A0S Series 12 페이지. 3/8” diaphragm pump
GENERAL DESCRIPTION
The ARO diaphragm pump offers high volume delivery even at low air
pressure and a broad range of material compatibility options available.
Refer to the model and option chart. ARO pumps feature stall resistant
design, modular air motor / fluid sections.
Air operated double diaphragm pumps utilize a pressure differential in
the air chambers to alternately create suction and positive fluid pressure
in the fluid chambers, ball checks insure a positive flow of fluid.
Pump cycling will begin as air pressure is applied and it will continue to
pump and keep up with the demand. It will build and maintain line pres-
sure and will stop cycling once maximum line pressure is reached (dis-
pensing device closed) and will resume pumping as needed.
AIR AND LUBE REQUIREMENTS
WARNING EXCESSIVE AIR PRESSURE. Can cause pump
damage, personal injury or property damage.
S
A filter capable of filtering out particles larger than 50 microns should
be used on the air supply. There is no lubrication required other than
the "O" ring lubricant which is applied during assembly or repair.
S
If lubricated air is present, make sure that it is compatible with the "O"
rings and seals in the air motor section of the pump.
S Santoprene R is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. S LubriplateR is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company) S
PE03P-X-X-A0S (en)
TYPICAL CROSS SECTION
S HytrelR and VitonR are registered trademarks of the DuPont Company S KynarR is a registered trademark of Arkema Inc. S
OPERATING INSTRUCTIONS
S
Always flush the pump with a solvent compatible with the material
being pumped if the material being pumped is subject to "setting up"
when not in use for a period of time.
S
Disconnect the air supply from the pump if it is to be inactive for a few
hours.
S
The outlet material volume is governed not only by the air supply but
also by the material supply available at the inlet. The material supply
tubing should not be too small or restrictive. Be sure not to use hose
which might collapse.
S
When the diaphragm pump is used in a forced-feed (flooded inlet)
situation, it is recommended that a "Check Valve" be installed at the
air inlet.
S
Secure the diaphragm pump legs to a suitable surface to insure
against damage by vibration.
MAINTENANCE
S
Certain ARO "Smart Parts" are indicated which should be available
for fast repair and reduction of down time.
S
Provide a clean work surface to protect sensitive internal moving
parts from contamination from dirt and foreign matter during service
disassembly and reassembly.
S
Keep good records of service activity and include pump in preven-
tive maintenance program.
S
Service Kits are available to service two separate Diaphragm Pump
functions: 1. AIR SECTION, 2. FLUID SECTION. The Fluid Section
is divided further to match typical active MATERIAL OPTIONS.
Figure 2
Page 3 of 12