ARO 8515-A 운영자 매뉴얼 - 페이지 3
{카테고리_이름} ARO 8515-A에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ARO 8515-A 19 페이지. “o” series “qrt” screwdrivers
ROUTINE LUBRICATION REQUIREMENTS
M30
33
Lack of or an excessive amount of lubrication will affect the perfor-
mance and life of this tool. Use only recommended lubricants at
below time intervals:
EVERY 8 HOURS OF TOOL OPERATION - Fill lubricator reser-
voir of recommended F.R.L. with spindle oil (29665). If an in line or
air line lubricator is not used, apply several drops of spindle oil
(29665) in air inlet.
EVERY 160 HOURS OF TOOL OPERATION - Lubricate clutch
parts with molybdenum grease (400361).
Lubricate gearing.
Pack bearings, coat shafts and lubricate gears with NLGI #1 "EP"
grease (33153). Gearing should contain approximately 1/8 oz.
(3.5 g) of grease per reduction.
AIR SUPPLY REQUIREMENTS
For maximum operating efficiency, the following air supply specifi-
cations should be maintained to this air tool:
l
AIR PRESSURE - 90 p.s.i.g. (6.2 bar)
l
AIR FILTRATION - 50 micron
l
LUBRICATED AIR SUPPLY
l
HOSE SIZE - 5/16" (8 mm) I.D.
An ARO
model C28231-810 air line FILTER/REGULATOR/LU-
BRICATOR (F.R.L.) is recommended to maintain the above air
supply specifications.
RECOMMENDED LUBRICANTS
After disassembly is complete, all parts, except sealed or shielded
bearings, should be washed with solvent. To relubricate parts, or
for routine lubrication, use the following recommended lubricants:
Where
ARO
Description
Air Motor
29665
1 qt Spindle Oil
.
"O" Rings & Lip Seals
36460
4 oz. Stringy Lubricant
Gears and Bearings
33153
5 lb. "EP" - NLGI #1 Grease
Clutches
40036-1
1 lb. "EP" Molybdenum Disulfide
Tool maintenance and repair shall be performed by authorized,
trained, competent personnel. Tools, hose and fittings shall be re-
placed if unsuitable for safe operation and responsibility should
be assigned to be sure that all tools requiring guards or other safe-
ty devices shall be kept in legible condition. Maintenance and re-
pair records should be maintained on all tools. Frequency of
repair and the nature of the repairs can reveal unsafe application.
Scheduled maintenance by competent authorized personnel
should detect any mistreatment or abuse of the tool and worn
parts. Corrective action should be taken before returning the tool
for use.
Disassembly should be done on a clean work bench with a clean
cloth spread to prevent the loss of small parts. After disassembly
is completed, all parts should be thoroughly washed in a clean sol-
vent, blown dry with air and inspected for wear levels, abuse and
contamination. Double sealed or shielded bearings should never
be placed in solvent unless a good method of m-lubricating the
bearing is available. Open bearings may be washed but should
not be allowed to spin while being blown dry.
Upon reassembling, lubricate parts where required. Use 33153
grease, or equivalent, in bearings. Use 36460 lubricant for "O"
ring assembly. When assembling "O" rings or parts adjacent "O"
rings, care must be exercised to prevent damage to the rubber
sealing surfaces. A small amount of grease will usually hold steel
balls and other small parts in place while assembling.
When replacement parts are necessary, consult drawing contain-
ing the part for identification.
Always use clean, dry air. Dust, corrosive fumes and/or excessive
moisture can damage the motor of an air tool. An air line filter can
greatly increase the life of an air tool. The filter removes rust,
scale, moisture and other debris from the air lines. Low air pres-
sure (less than 90 p.s.i.g.) reduces the speed of the air tool. High
air pressure (more than 90 p.s.i.g.) raises performance beyond
the rated capacity of the tool and could cause injury. Shown below
is a typical piping arrangement.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
INSPECTION, MAINTENANCE AND INSTALLATION
SYSTEM
n
Disconnect air supply from the tool or shut off air supply and ex-
haust (drain) line of compressed air before performing mainte-
nance or service to the tool.
It is important that the tools be serviced and inspected at regular
intervals for maintaining safe, trouble-free operation of the tool.
Be sure the tool is receiving adequate lubrication, as failure to lu-
bricate can create hazardous operating conditions resulting from
excessive wear.
REGULATOR
BRANCH LINE 2 TIME/
AIR TOOL INLET SIZE
DRAIN REGULARLY
Be sure that the air supply lines and connectors are of proper size
to provide a sufficient quantity of air to the tool.
3