ASL INTERCOM PS 280 User Manual - Page 5

Browse online or download pdf User Manual for Power Supply ASL INTERCOM PS 280. ASL INTERCOM PS 280 7 pages. Dual channel power supply pro series

5.0

FRONT PANEL CONTROLS

1 POWER ON/OFF switch
Mains power push button for switching ON and OFF
the internal power supply.
2 OVERLOAD LED
This LED illuminates if the internal power supply has
shut off line power due to overload.
If the internal power supply is overloaded (too many
user stations are connected or short-circuit in the
interconnecting cables or thermal overload), it activates
a circuit-breaker which immediately shuts off line
power. This circuit breaker resets automatically 3
seconds after the overload situation is terminated,
restoring line power automatically.
During short-circuit, the overload LED extinguishes
very shortly every 3 seconds. During thermal overload
the LED burns continuously.
This overload LED also comes on every time you
switch on the main power.
6.0
REAR PANEL CONTROLS & CONNECTORS
7 A & B LINE connectors
These XLR-3 type connectors are for connecting user
stations, via standard microphone cable.
There are two connectors for channel A and two
connectors for channel B.
Pin assignments :
1. 0 V / ground shield
2. +30 V power wire
3. audio wire
8 AUX INPUT connector
This XLR-3 type aux input is electronically balanced
and accepts audio levels between -18dBu to +22dBu
on line level, and -38dBu to +2dBu on mic level.
Pin assignments :
1. 0V / ground
2. Signal +
3. Signal -
When mic level is selected, a +30V DC phantom power
is supplied to pins 2 and 3.
4
3 POWER LED
This LED illuminates if line power is supplied by the
internal power supply.
4 ALL MIC'S ON/OFF button
With this pushbutton all microphones of the connected
stations can be muted.
5 ALL BUZZERS ON/OFF button
With this button all buzzers of the connected stations
can be muted.
6 AUX VOLUME control knobs
These knobs adjusts the level of the aux input signal to
each of the two intercom lines.
9 FUSE
This fuse protects the PS 280 against severe internal
damage, in case of malfunction in the power section.
To remove the fuse the mains cord must be removed.
It is most important to place the correct fuse in the
holder :
mains voltage
fuse
220 - 240 VAC T 315 mA
100 - 120 VAC T 630 mA
Spare fuses will be found in the small packet supplied
with the unit.
10 MAINS INLET
IEC Mains connector. For correct wiring and operation
refer to section 4.0.
Before you plug in the mains voltage, check if:
The fuse is correct
The voltage is correct
User Manual PS 280 / Issue 1 © 1994 ASL Intercom, Utrecht, Holland.
WARNING