AMCI ME15 Manual - Page 5
Browse online or download pdf Manual for Media Converter AMCI ME15. AMCI ME15 15 pages. Magnetic encoder
ME15 Magnetic Encoder Manual
Revision 1.1
ME15 SSI OPTION
Supply Voltage........................5 - 30VDC (+/- 5%)
Power Consumption...................< 0.5W
Measuring Range......................360°.
Resolution/Code.......................10 Bit / Binary
Position Accuracy.....................0.5°
Linearity.................................< 0.5%
Repeat Accuracy........................< 0.1%
SSI Interface:
Clock Frequency......................100 KHz – 1 MHz
Output Driver..........................RS 485 (TIA/EIA Compliant)
Short circuit proof outputs:..........Yes ∗
∗ Short circuit to 0V (DC Return) or to output, when supply voltage is correctly applied.
The M15 SSI device has two options of operation: Standalone Option or Multiplexing Option. When M15 works as
Standalone SSI device, data is continuously read-out by simply applying SSI Clock signal with Enable line pulled low
(i.e. tied to the DC Return). When M15 works as Multiplexing SSI device, Enable line determines whether particular
M15's input/output driver is enabled (Enable Input low) or disabled (Enable Input high). Only one unit at the time is
supposed to be enabled and all others disabled.
SSI Protocol
The serial data transmission timing is outlined in Figure 1: With the first falling edge of the clock (CLK) signal, data is
latched into the output shift register. Each subsequent rising CLK edge shifts out one bit data.
The serial word contains 16 bits. The first 10 bits D[9:0] are the absolute angular position data (MSB is clocked out
first). The subsequent 6 bits contain system information; about validity of data such as OCF (Offset Compensation
Finished), COF (Cordic Overflow), LIN (Linearity Alarm), Parity and Magnetic Field status (increase / decrease / out
of range) and they are used for diagnostic purposes only.
Figure 1: Synchronous serial interface with absolute angular position data
20 Gear Drive, Plymouth Industrial Park, Terryville, CT 06786
page: 5
Tel: (860) 585-1254
Fax: (860) 584-1973
Web: www.amci.com