Akw M11 DigiPump Installation And User Care Instructions - Page 16

Browse online or download pdf Installation And User Care Instructions for Plumbing Product Akw M11 DigiPump. Akw M11 DigiPump 20 pages.

Akw M11 DigiPump Installation And User Care Instructions

Care and Maintenance

The integrity of the case and the RCD device operation must be checked quarterly
as part of a routine safety and maintenance activity on the installation.
If the case shows any mechanical damage the unit must be isolated electrically and
the entire unit replaced.
Pipework connections must be made to the unit with sufficient clearance (100mm
minimum separation to any pipe bend or fitting adjacent to the inlet/outlet
connections) to permit removal of the pump/head for routine maintenance and
replacement.
The unit must be regularly cleaned using normal bathroom cleaning materials and
rinsed down with clean water and wiped dry with a soft cloth to remove any cleaning
residue.
Do not use strong or concentrated acidic or alkaline cleaning materials as these may
discolour or otherwise damage the product. Do not use an abrasive cloth.
Problem solving
PUMP WILL NOT START
Please refer to pump instructions to ensure the pump is installed
correctly.
Ensure flow sensor is connected to pump controller and power is
on to pump controller.
Ensure that all pipe work is fully flushed before the flow sensor is
installed, and the in-line strainer is in place.
Check flow sensor is installed in right orientation
(Flow direction arrow moulded on the casing).
Most flow sensor problems are due to debris being caught inside
the flow sensor. Remove sensor and check for debris.
If required reverse flush with water.
16