Technical data
9
Technical data
9.1
Technical data - electrical ratings
• Interference immunity:
• Emitted interference:
• Approval:
9.2
Technical data - electrical ratings (encoder)
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Output frequency:
• Output signals:
• Output stages:
• Sensing method:
9.3
Technical data - electrical ratings (centrifugal switch)
• Switching accuracy:
• Switching deviation cw-ccw rotation:
• Switching hysteresis:
• Switching outputs:
• Output switching capacity:
• Minimum switching current:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
9)
35
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE
9...30 VDC
(HTL-P, TTL - version R)
9)
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
≤120 kHz
≤300 kHz option
K1, K2, K0 + inverted
Error output (option EMS)
HTL-P (power linedriver)
TTL/RS422
(as ordered)
Optical
±4 % (Δn = 2 rpm/s)
≤ +20 % (Δn = 1500 rpm/s)
≤3 %
~40 % of switching speed
1 output, speed control
≤6 A / 230 VAC
≤1 A / 125 VDC
50 mA
Baumer_HOG10-FSL-T2_II_DE-EN (17A2)
MB071.1T2 - 11069399