8
4
Montage / Mounting

Technical data

8
Technical data
8.1

Technical data - electrical ratings

• Interference immunity:
• Emitted interference:
• Approvals:
8.2

Technical data - electrical ratings (square-wave)

• Voltage supply (Signals):
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
8.3

Technical data - electrical ratings (SinCos)

• Voltage supply (Signals):
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Reference signal:
• Sensing method:
• Output signals:
• Output stage:
• Difference of SinCos amplitude:
• Harmonics typ.:
• DC offset:
• Bandwidth:
At +UB = 5 VDC: TTL/RS422; At +UB = 10...30 VDC: HTL
4)
23
EN 61000-6-2
EN 61000-6-3
CE
UL
RN...C:
4.5...30 VDC
TN...C:
5 VDC ±5 %
HN...C:
10...30 VDC
UN...C:
5...30 VDC
≤160 mA
64...131072 (as ordered)
90° ±10°
40...60 %
Zero pulse, width 90°
Magnetic
≤2 MHz
A+, B+, R+, A−, B−, R−
HTL
TTL/RS422
(as ordered)
PN...C:
4.5...30 VDC
≤160 mA
64...8192 (as ordered)
90° ±5
Zero pulse, width 90°
Magnetic
A+, B+, R+, A−, B−, R−
SinCos 1 Vpp
≤20 mV
-40 dB
≤20 mV
400 kHz (-3 dB)
Baumer_MHGP100-T1_DE_EN_202210_MI_11121634 (22A1)
(TTL/RS422)
(TTL/RS422)
(HTL)
(TTL/HTL)
4)
MB210T1 - 11121634