ELECTRICAL CONNECTION / TERMINAL SIGNIFICANCE
5.
ELECTRICAL CONNECTION
5.1
Terminal significance
+UB
A+
A _
B+
B _
R+
R _
nE+
nE _
PRE
DIR
SP+*
SP _ *
SA*
SB*
D+
D _
C+
C _
dnu
* Only at version with speed switch
** Depending on the version
13/33
Voltage supply
Ground
Channel A+
Channel A _ (channel A+ inverted)
Channel B+
Channel B _ (channel B+ inverted)
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / error output
System OK _ / error output inverted
PRESET/RESET
Rotating direction
DSL_OUT1 / speed switch (Open-Collector** or Solid State Relay**)
DSL_OUT2 / speed switch (0 V** or Solid State Relay**)
RS485+ / programming interface
RS485 _ / programming interface
DATA+ (SSI)
DATA _ (SSI)
CLOCK+ (SSI)
CLOCK _ (SSI)
Do not use