9
Technical data
9.1
Technical data - electrical ratings
Voltage supply:
Consumption w/o load:
Pulses per revolution:
Phase shift:
Duty cycle:
Reference signal:
Sensing method:
Output frequency:
Output signals:
Output stages:
Interference immunity:
Emitted interference:
Approvals:
9.2
Technical data - mechanical design
Size (flange):
Shaft type:
Admitted shaft load:
Flange:
Protection EN 60529:
Operating speed:
Operating torque:
Rotor moment of inertia:
Materials:
Operating temperature:
Resistance:
Corrosion protection:
Explosion protection:
Connection:
Weight approx.:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
1)
MB069b - 11117426
BAUMER_POG10-ET_DE_EN_202212_MI_11117426 (22A3)
9...30 VDC
(HTL-P, TTL - version R)
1)
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz, ≤300 kHz option
K1, K2, K0 + inverted
HTL-P (power linedriver)
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL
ø115 mm
ø11 mm solid shaft
≤300 N axial, ≤450 N radial
EURO flange B10
IP66
≤12000 rpm (mechanical)
2 Ncm
212 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-40 °C...+100 °C
-25 °C...+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see
IEC 60068-2-6
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
Connecting terminal
3.1 kg
Technical data
section
2.
22