4.3.2
Cone shaft
)
Service life restrictions and angle error by runouts
High runout of the drive shaft can cause device angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the ser-
vice life of the device�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The device must be mounted with cable connection facing downward and not
exposed to water�
MB258EN - 11196411, 21A1, Baumer_HMG10-Inc_EN_202103_MI_11196411
18�
10b
10c
10a
5
10e
10d
MOUNTING / MOUNTING TO THE DRIVE SHAFT
10c 10b
10b
9
10c
1,6x8 mm
17 mm
7a
11b
11a
M
= 3���4 Nm
t
10 mm
section 4.5,
TX 20
2
3
5 mm
13/40