Baumer MHGP 200 Mounting And Operating Instructions - Page 26

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer MHGP 200. Baumer MHGP 200 28 pages. Magnetic sensing

Baumer MHGP 200 Mounting And Operating Instructions
8
4

Technical data

Montage / Mounting
8
Technical data
8.1

Technical data - electrical ratings

• Interference immunity:
• Emitted interference:
• Approvals:
8.2

Technical data - electrical ratings (square-wave)

• Voltage supply (Signals):
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
8.3

Technical data - electrical ratings (SinCos)

• Voltage supply (Signals):
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Reference signal:
• Sensing method:
• Output signals:
• Output stage:
• Difference of SinCos amplitude:
• Harmonics typ.:
• DC offset:
• Bandwidth:
At UB = 5 VDC: TTL/RS422; At UB = 10...30 VDC: HTL
4)
23
EN 61000-6-2
EN 61000-6-3
CE
UL approval / E217823
RN...C:
4.5...30 VDC
TN...C:
5 VDC ±5 %
HN...C:
10...30 VDC
UN...C:
5...30 VDC
≤160 mA
128...262144 (as ordered)
90° ±10°
40...60 %
Zero pulse, width 90°
Magnetic
≤2 MHz
A+, B+, R+, A−, B−, R−
HTL
TTL/RS422
(as ordered)
PN...C:
4.5...30 VDC
≤160 mA
128...16384 (as ordered)
90° ±5
Zero pulse, width 90°
Magnetic
A+, B+, R+, A−, B−, R−
SinCos 1 Vpp
≤20 mV
-40 dB
≤20 mV
400 kHz (-3 dB)
Baumer_MHGP200-T1_II_DE-EN (19A2)
(TTL/RS422)
(TTL/RS422)
(HTL)
(TTL/HTL)
4)
MB211T1 - 11105827