10.3

Type data

Open-cir-
cuit voltage
Type
[mV/rpm]
TDP0,09LT-1
TDP0,09LT-2
TDP0,09LT-7
TDP0,09LT-3
TDP0,09LT-8
TDP0,09LT-9
TDPZ0,09LT-1
TDPZ0,09LT-2
TDPZ0,09LT-3
Superimposed ripple (for τ
10.4

Replacement switching diagram

Polarity for positive direction of rotation, see section 5:
TDP:
TDPZ: 1A1/2A1: +
R
L
A
A
U
(n)
0
Tachogenerator
τ
≈ R · C
τ
RC
MB110 - 11055720
Baumer_TDP009-TDPZ009_II_DE-EN (19A2)
Minimum load required
depending on speed range
(DC)
0 - 3000:
U
R
0
L
[kΩ]
10
≥0.75
20
≥3
30
≥6.8
40
≥12
50
≥19
60
≥27
Twin tachogenerator with two separate tachogenerator voltages
(The data refer to each of the two tachogenerator outputs)
10
≥3
20
≥12
40
≥48
= 0.7 ms):
RC
A1: +
A2: -
1A2/2A2: -
R
A1
U(n)
R
L
A2
L
A
R
A
L
[rpm]
0 - 6000:
0 - n
max
R
R
L
L
[kΩ]
[kΩ]
≥0.3
≥8.5
≥12
≥34
≥27
≥75
≥48
≥134
≥75
≥134
≥108
≥134
≥12
≥28
≥48
≥109
≥192
≥433
≤0.55% peak-peak
(VDE)
(VDE)
C
U(n) = U
(n)
0
Maximum
Armature
operating
resistance
speed
:
n
R
max
A
[rpm]
10000
10000
10000
190
10000
320
8000
492
6700
750
9000
9000
140
9000
698
≤0.25% rms
U(n)
-n
-U(n)
R
L
≈ U
(n) for R > R
R
+ R
0
A
L
10
Armature
inductance
(20°C)
L
A
[Ω]
[mH]
20
18
82
75
167
300
465
675
35
23
88
350
U
(n) ≈ U(n)
0
n
>> R
L
A
22