DPI Xcel 7QP-12F950P25-C01 Manual - Page 9

Browse online or download pdf Manual for Battery Charger DPI Xcel 7QP-12F950P25-C01. DPI Xcel 7QP-12F950P25-C01 15 pages. 10-channel/bank 6,8,12v battery charger

LCD Display:
At Power-On:
 The LCD Backlight illuminates
 For approximately 5 seconds, the CHARGE MODE and Battery Type are
displayed
 For approximately 5 seconds the SOFTWARE VERSION displayed
After approximately 10 seconds, the display defaults to displaying Channel-1
shown as CH01 in the upper left corner of the LCD display. Depress/Release
the MENU Button to increment the display to an alternate channel.
When battery is connected, LCD Displays:
1. Upper left corner of LCD Displays the channel number. CH01 is 'Channel-1
2. 'VOLT' is the measured voltage of the battery – this is a voltmeter function.
3. 'AMPS' is the charge current flowing into battery – this is an ammeter
function.
4. Bottom left of LCD displays the charge status. Typical messages are:
a. cPQT - Pre-Qualification Charging – testing battery
b. cCCT - Constant Current Stage Charging battery
c. cCVT - Constant Voltage Stage Charging battery
d. cTOP - Top-Off Stage Charging battery
e. cFIN - Float/Maintenance Stage - Charge finished
When no battery is connected, the bottom left corner of the LCD displays 'NoBt'.
This corner also displays other codes when necessary and are referenced
throughout this manual.
LOG ERROR
ERROR MESSAGE
CODE
ERR05
B/Cel Wrong Type
ERR24
Chg.Stg Timer-00
ERR25
Chg.Stg Timer-01
ERR07
BatPack UnBal -V
ERR26
Chg.Stg Timer-02
ERR08
BatPack UnBal -A
ERR27
Chg.Stg Timer-03
ERR13
BatLoad Overload
CHARGE ERROR TABLE
DESCRIPTION
Battery voltage higher
than expected
Safety timer timed out
Safety timer timed out
Battery cells
unbalanced
Safety timer timed out
Battery cells
unbalanced
Safety timer timed out
Battery over loaded by
external load
9
ERROR
12V Battery connected to
6V MODE setting
Battery capacity incorrect
for charger MODE setting
Battery capacity incorrect
for charger MODE setting
Defective Battery
Battery capacity incorrect
for charger MODE setting
Defective Battery
Battery capacity incorrect
for charger MODE setting
Heavy Battery load during
FLOAT charge
POSSIBLE CAUSE
(REMEDY)