Connections
READER
You can connect the building cable to the reader in either of two
ways:
use the four-pin socket and cord supplied with the reader and
join the cord to the building cabling; or
provide your own Molex 6471 crimp terminal socket and
terminate the building cable directly to it.
In either case, ensure that you use the socket grommet supplied with
the reader.
If you supply your own socket, use the cable terminating tool. The
tool has a head (Part No. C861145) and handle (Part No. C861115).
Pin number 4 of the socket feeds into the cable terminating tool
first.
The other end of the building cable connects to one of the
following:
Cardax FT Controller 3000
Cardax FT Reader I/O Interface
Cardax FT URI
Part number 3C4480 R10
May 2005
INTERCONNECT BOARD
CRIMP TERMINAL SOCKET
4
3
2
1
(VIEWED FROM
CABLE SIDE OF CONNECTOR)
CABLE SIDE OF SOCKET)
1
1
2
2
3
3
4
4
INTERCONNECT BOARD
1
2
3
4
(VIEWED FROM
READER SIDE OF CONNECTOR)
MOLEX 6471
4 3 2 1
(VIEWED FROM
1
RED
2
WHITE
3
BLUE
4
BLACK
+12V
DATA OUT
FT CONTROLLER 3000;
FT READER I/O INTERFACE; OR
FT URI
DATA IN
-12V
7