AS6200 Adapter Board
4.2
Temperature Register
D15
D14
D13
T11
T10
T9
The temperature register contains the digitally converted temperature value. It
consists of 2 byte and can be converted according to the following formula:
Positive values= |Value| / LSB
Negative values= Complement( |Value| / LSB ) + 1
Example +75°C
75° / 0.0625° = 1200 = 0100 1011 0000 = 40
Example -40°C
| −40° | / 0.0625° + 1 = 640 + 1 = 0010 1000 0000 + 1 = 1101 0111 1111 + 1 =
1101 10000 0000 = 80
ams Eval Kit Manual
[v1-01] 2017-Dec-01
D12
D11
D10
D9 D8 D7 D6 D5 D4 D3 D2 D1
T8
T7
T6
T5
MSB Byte
Table 6: Temperature Register
T4
T3
T2
T1
T0
LSB Byte
D0