Anderson VFI84 Operation Manual - Page 6

Browse online or download pdf Operation Manual for Burner Anderson VFI84. Anderson VFI84 15 pages.

Number
110/150
170/180
310
390

5.3 Pilot burner

VFI84 Series Burner has a separated pilot burner of maximum capacity 50kw.User need
to supply fresh combustion air for pilot burner, typically a small air blower or
compressed air need to apply to pilot burner. According to pilot burner's manual, 5 mbar
combustion air and 3 mbar gas pressure is necessary for pilot burner operation
continually. These pressure requirements satisfy combustion chamber with neutral
pressure, if oven chamber pressure exists, chamber pressure needs to be added to the
pressure value mentioned above. It should be noted that the depth of pilot burner
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions – VFI84 Burner Operation Manual
Name
peep sight
burner body
pilot burner
chamber pressure test
Fig2 VFI84 Series Burner diagram
Number
Name
140
air pressure switch
200
installation handle
370
UV installation point
410
gas inlet flange
4