Bosch WTA74202ID Installation And Operating Instructions Manual - Page 18
Browse online or download pdf Installation And Operating Instructions Manual for Dryer Bosch WTA74202ID. Bosch WTA74202ID 40 pages.
Installation and connection
en
Installation option
Notes
Route the exhaust air duct in such a
■
way that the dryer cannot draw the
moist, warm exhaust air back again.
The outlet for the exhaust air must
■
be designed or positioned in such a
way as to prevent any additional
backpressure (e.g. from a direct
ingress of wind) in the escaping
exhaust air, e.g. by using 90°, facing
down ~ Page 19
The outlet for the exhaust air duct
■
must be no more than 2.5 m higher
than the exhaust air opening on the
appliance.
Installation options for the exhaust air
duct:
Through a wall box into the open
■
air
Example: pipe connection - inside
diameter = 100 mm, smooth
A = straight piece (1.0 m)
B = curved pipe (R = 200 mm)
C = straight piece (1.5 m)
D = pipe elbow
E = telescopic wall box with grid 14
Total pressure loss
18
Directly into the open air
■
Route the exhaust air duct directly
into the open air via an exhaust air
pipe through an open window.
Example: pipe connection - inside
diameter = 100 mm, flexible pipe,
corrugated
A = curved pipe (R = 300 mm)
B = straight piece (1.5 m)
C = curved pipe (R = 100 mm)
D = straight piece (0.5 m)
Total pressure loss
4
4
6
Through a wall box into chimneys or
19
■
ventilation shafts
Notes
47
– It is not permitted to connect the
– If the appliance is being
exhaust air duct to chimneys
which are connected to gas or
coal-fired ovens/cookers or gas-
fired heating systems.
connected to a moisture-
insulated ventilation shaft the
reponsible chimney sweep must
be informed and the approval of
the local building department
(building supervision office) or
the owner of the building must be
obtained.
7
18
10
6
41