Atkinson Electronics GSCM-MINI Manual - Page 7

Browse online or download pdf Manual for Control Unit Atkinson Electronics GSCM-MINI. Atkinson Electronics GSCM-MINI 8 pages. Generator start control module
Also for Atkinson Electronics GSCM-MINI: Manual (16 pages)

Atkinson Electronics GSCM-MINI Manual
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
LED DESCRIPTION (WHAT THEY MEAN)
1.
one blink every 5 seconds = Ready mode, looking for a start signal;
Start:
one blink every 2.5 seconds = auto start mode operation;
one blink every other second= auto start/stop period,
continuous = manual start signal received;
fast blink = 60 second delay after start signal removed before generator started;
2.
fast blink = over speed condition;
Generator Hz
slow blink = under speed condition;
Shutdown:
double blink = Maximum Crank attempts reached, Failed to Start;
continuous = start function disabled, AC Hz detected before starting;
3.
continuous = GSCM has a valid run signal from generator;
Run:
4.
continuous = GSCM is in a fault condition and requires a reset;
Fault:
5.
continuous = Status of K1 and K2 Relays "ON"
K1 & K2:
SPECIFICATIONS
SIZE & WEIGHT:
5.13" L x 2.853" W x 1.35" H, 20 OZ
MOUNTING:
2 screws through tabs
POWER:
12VDC only
Quiescent current < 10mA
Relay current < 25mA ea.
MANUAL INPUT:
B+ (12VDC) input = on condition
Open input = off condition
BATTERY INPUT:
0-60V DC
AUTO START/
STOP THRESHOLD: 12V System 11.5V,
24V System 23.0V,
48V System 46.0V,
APPLICATION 2 - REMOTE RV GENERATOR START CONSOLE REPLACEMENT
ATKINSON ELECTRONICS, INC.
Web Site: www.atkinsonelectronics.com
Start
Stop
13.5V
27.0V
54.0V
Distributed by:
RELAY CONFIG.:
Open input = Momentary Crank
(TERMINAL 6)
Grounded input = Maintained Crank
B+ (12VDC) input = Ignition & Crank
FREQUENCY INPUT: 120-240V AC 0-100 Hz
OUTPUT RATINGS: Qty. (2) 10 Amp 28V DC, 240V AC
Relay contacts
Qty. (2) Open collector NPN
transistors, Max. 300mA each
FAULT DETECTION: Start Failure, (3 attempts)
Over Hz condition (10 seconds)
Under Hz condition (10 seconds)
AMBIENT TEMP:
-40 to 85 C
GSCM-MINI
SECTION - 8
SECTION - 9
The GSCM mini can be used
to replace a typical remote
generator control console, that
is mounted on the dash of a
motorhome. Instead of a large
console and cable, use a
small 16 to 18 gauge 4 wire
signal cable, an on-off switch
with built in light and a
separate 12vdc fault light.
When the remote switch is
turned on, the GSCM mini
starts the generator. After the
generator starts and comes up
to speed the "run" LED lights
on the GSCM mini and lights
the remote start switch light. If
the generator fails to start or
fails while commanded to run
the "fault" LED on the GSCM
mini lights along with the
remote fault
12vdc
light.
Turning off the power to the
GSCM mini resets the fault
condition and it is ready to
receive
another
start
command.
REV 9/05