ArcLine DVP Integral
Max. load of the Data Configurator is 40 Arcline DVP Integral fixtures regardless of type of used modules (40 x
ArcLine 600 DVP Integral or 40 x ArcLine 900 DVP Integral or ArcLine 1200 DVP Integral or their combinations e.g
10 x ArcLine 600 DVP Integral + 30 x ArcLine 1200 DVP Integral). These 40 Arcline DVP Integral fixtures can be
connected to the one LED output of the Data Configurator or divided into both LED outputs (e.g. Output A=10
fixtures, output B=30 fixtures).
Maximum distance between the Data configurator and the last connected fixture must not exceed 100m at each
LED output.
If you combine different types of ArcLines DVP Integral in one installation and you need to place them
close in a row, the Connection cables ArcLine DVP-to- ArcLine DVP will be necessary in some cases because each
type of the ArcLine DVP Integral has a different length of the supply cable.