DSC LC-103PIMSK Installation Instructions - Page 2
Browse online or download pdf Installation Instructions for Security Sensors DSC LC-103PIMSK. DSC LC-103PIMSK 2 pages. Professional passive infrared & microwave detector with anti-mask with pet immunity
SETTING - UP THE DETECTOR
LED CONTROL
Switch 1 of DIP-4. Use for Setting "LED" - LED Enable / Disable
Position Up "ON" - LED ENABLE The RED LED will activate when the detector is in alarm condition. Position Down "OFF" - LED DISABLE
The LED's are disabled.
NOTE: the state of the switch "LED" - does not affect the operation of the relay. When an intrusion is detected, the LED will activate and the alarm
relay will switch into alarm condition for 2 sec.
ANTI MASK FUNCTION
Switch 2 of DIP-4. Use for Setting "AM" - Anti Mask function
Position Up "ON" - protection against masking the detector from 0.4m and closer. Position Down "OFF" - protection against masking the
detector from 0.8m and closer.
PIR SENSITIVITY ADJUSTMENT
S w it ch 3 of D IP- 4. Use f o r S et t in g "P IR" - pr o vi des s en si tiv i ty co ntr ol of PIR ac co rd in g to the env i ro nme nt.
Position Up "ON" - gh sensitivity For stable environments. Position Down "OFF" - Low sensitivity For harsh environments. This setting
enables special software to modify detection speed.
PET IMMUNITY SETTING
Switch 4 of DIP-4. Use for Settings "PET" 15kg-25kg
P os itio n Up " ON " Im muni ty to an anim al up to 15 kg Po sit ion D ow n "O F F " Im muni ty to an anim al up to 25 kg
SENSITIVITY CALIBRATION
The MW potentiometer adjusts the detection sensitivity of Doppler between 40% and 100% (factory set to 65%). Rotate the potentiometer
clockwise to increase sensitivity. Rotate the potentiometer counter-clockwise to decrease sensitivity.
The PIR potentiometer adjusts the detection range between 68% and 100% (factory set to 84%). Rotate the potentiometer clockwise to increase
range, counter-clockwise to decrease range.
NOTE: You must reset the detector from Control Panel before the new settings will take effect.
TEST PROCEDURE
Wait for one minute warm up time after applying 12 Vdc power. Conduct testing with the protected ar ea clear ed of all people.
WALK TEST: 1. Remove front cover. Set LED to ON position. 2. Reassemble the front cover. 3. Start walking slowly across the detection zone.
4. Observe that the red LED lights whenever motion is detected. 5. Allow 5 sec. between each test for the detector to stabilize. 6. After the walk
test is completed, you can set the LED to OFF position.
NO TE: Walk tests s houl d be conducted, at l eas t once a year, to confirm proper operation and c overage of the detec tor.
TECHNICAL SPECIFICATION
Detection Method
Quad (Four element) PIR &
microwave pulse Doppler
Power Input
8.2 to 16 Vdc
Current Draw
Active: 25.5 mA
Standby: 18 mA
Temp.
Compensation
YES
Alarm Period
2 +/- 1 sec
Alarm Output
N.C 28Vdc 0.1 A with 10 Ohm
series protection resistors
Tamper Switch:
N.C 28Vdc 0.1A with 10 Ohm
series protection resistor -
open when cover is removed
Warm Up Period
1 min
LED Indicator:
LED's
are blinking during warm up period
and self testing,
Red LED:
ON during alarm
Green LED:
PIR CHANNEL
Yellow LED:
MW CHANNEL
Dimensions:
118mm x 62.5mm x 41mm
(4.65" x2.46" x1.61")
Weight:
120 gr.
LIMITED WARRANTY: Digital Security Controls Ltd, warrants that for a period of 12 months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfillment of any
breach of such warranty. Digital Security Controls Ltd shall, at its option, repair or replace the defective equipment upon returns of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to
damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls Ltd, such as lightning, excessive voltage mechanical shock, water damage, or damage arising out of abuse, alteration or
improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd. Digital
Security Controls Ltd neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation
or failure of this product.
Motion detectors can only detect motion within the designated areas as Shown in their respective installation instructions. They cannot discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area
protection. They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass
doors or windows. Any
type of tampering whether intentional or unintentional such as masking , painting, or spraying of any material on the lenses, mirrors, windows or any other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are intentional or unintentional sources
of heat in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on.
WARNING: Digital Security Controls Ltd, recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and d ue to, but not limited to, criminal tampering or electrical disruption,
it is possible for this product to fail to perform as expected.
Imp o rtan t info rmatio n: Ch ang es o r mo di fi cation s n ot exp ressl y ap pro ved by D igi ta l Secu rity Co ntrol s Ltd cou ld voi d th e use r's au th ori ty to op erate thi s eq uip men t.
2005 Digital Security Controls Ltd
Toronto, Canada
www.dsc.com
FIG 5 - PCB Layout
BLOCK CONNECTOR
SWITCH FOR
PYROSENSOR
SETTINGS
1
3
FIG 6
Bra cket Instal latio n
Wall Mount Bracket
1
Ceiling Mount Bracke t
2
FIG 7 - Bracket options