Anzzi ENVO WH-AZ035-M1 Install & Operation Manual - Page 8
Browse online or download pdf Install & Operation Manual for Water Heater Anzzi ENVO WH-AZ035-M1. Anzzi ENVO WH-AZ035-M1 16 pages. Electric instant water heater
PRODUCT SPECIFICATIONS
Model
Voltage
Wattage
Rated Current
Min. required circuit breaker
Min. wire size (L,N,L1,L2,E)
Max. water pressure
Min. water flow to activate unit
Weight
Product Dimensions (D×H×W)
Water connections
Note: For supply connections, confirm using correct breaker size and wire gauge.
Connected only to a circuit that is protected by recognized ground-fault circuit
interrupter (GFCI).
INSTALLATION GUIDELINE
Make sure the appliance is intact, and the
●
fittings are complete.
Please make sure the main power supply,
●
water pressure, grounding condition,
ammeter and wire reach the standard of
installation requirement.
Clean all the impurities of the pipe by
●
allowing water to flow for a few minutes
before connecting the heater to the supply
line. Any residue or dirt in the pipes may
cause damage to the heater.
We strongly recommend installing a water
●
filter before the inlet of heater. Hard water or
water with high levels of minerals and alkali
can cause damage to this unit. Water
softening system is needed for this case.
PG.4
WH-AZ035-M1
120V
3500W
29.5A
32A
10 AWG
87 Psi (0.6 MPa)
0.4 GPM (1.5 L/min)
4.21 lbs
3.86" x 6.3" x 7.8"
1/2''NPT
It must be fitted with a pressure reducing
●
valve adjacent to the entrance when the inlet
pressure is higher than 150 Psi (1034kPa).
DO NOT install near tinder or a strong
●
magnetic field. The appliance can be installed
above or under the sink, and unit must only be
mounted with inlet & outlet pointing downward
or upward VERTICALLY near by the water
fittings.
It is recommended to install the appliance no
●
more than 4 ft from the point of use to save
power.
Avoid locations that are prone to dampness,
●
high humidity, moisture, or dust.
WH-AZ006-M1
240V
6000W
25A
32A
12 AWG