AirVerter AV-096 User Manual - Page 3
Browse online or download pdf User Manual for Paint Sprayer AirVerter AV-096. AirVerter AV-096 12 pages. Hvlp paint spray system
Air Compressor
A. Air compressors used with AirVerter
Guns must be able to HOLD a minimum of 40
PSI while spraying. Note: Position a
pressure gauge in the air hose nearest the
spray gun to be assured of the PSI required to
satisfactorily spray your coating.
®
B. The AirVerter
Inductor (AV-005) requires a
minimum 5 HP compressor.
A. The Model AV-096 Spray Gun operates with a
constant flow of air through the gun.
trigger controls the fluid flow only. The Model
96 Spray Gun requires an AirVerter
Assembly
between
compressed air supply.
B. Consult the Needle, Nozzle and Air Cap
Selection Guide to select the proper
combination for the coating and finish
quality desired.
create unnecessary overspray!
Using a One-Quart Paint Cup
A. Attach the 1-Quart Paint Cup (AV-188) to the
Fluid Tube Fitting (AV-9604) on the bottom of
the gun and tighten. Attach the Air Pressure
Tube on the cup lid to the Air Pressure Elbow
(AV-176) on the gun.
B. The 1-Quart Paint Cup must be airtight, clean
and free of obstructions.
• The seal between the paint cup lid gasket
and the lip of the cup MUST BE airtight.
• The Air Pressure Tube supplying air to the
paint cup MUST BE clean and free of
obstructions.
C. Never fill a 1-Quart Paint Cup more than ¾
full. This allows sufficient air space in the cup
for pressurization.
020) will reduce clean-up time and solvent
usage.
D. Attach an Inductor Assembly (AV-005) to the
male quick-disconnect at the base of the gun
handle.
DO NOT OPERATE SPRAY GUNS WITHOUT PERSONAL SAFETY EQUIPMENT
®
AirVerter
Model 96 HVLP Paint Spray System
EQUIPMENT REQUIREMENTS
®
Spray
OPERATING INSTRUCTIONS
®
Inductor
the
gun
and
Too much pressure will
Using a Cup Liner (AV-
High Pressure Air Hose
A. Air hose lengths up to 50 feet MUST have an
I.D. of 3/8" including fittings.
B. Air hose lengths greater than 50 feet MUST
have an I.D. of 1/2" including fittings.
Paint Cup, Pressure Pot or
Diaphragm Pump
Be certain to follow manufacturer's instructions.
Using a Two-Quart or Larger
The
Remote Pressure Pot
or Diaphragm Pump
the
A. Remove the Air Pressure Elbow (AV-176) and
replace it with the Air Pressure Plug (AV-177)
found in your parts kit.
B. Attach the fluid hose from your pressure pot to
the Fluid Tube Fitting (AV-9604) on the gun
and tighten.
C. Attach an Inductor Assembly (AV-005) to the
Male Quick Disconnect (AV-172) at the base
of the gun handle.
A.
Follow
the
Guidelines listed on the following page.
B. Before paint is poured into the cup or
diaphragm pump, make certain paint is
properly mixed. This is particularly true when
mixing multi-component paints.
shaker, rotary mixer, or paint paddle to achieve
a homogeneous mixture. (Hint: Split your paint
into two parts; the top will be lighter and the
bottom will be heavier.
bottom half of the paint and slowly add small
amounts of the top half into the heavier
bottom.)
C. Strain your paint to remove impurities. Use
a cone strainer or a 100-mesh nylon bag or
equivalent strainer.
D. Thin
your
manufacturer's specifications.
Before Spraying
Air
and
Paint
Completely stir the
paint
according
Management
Use a paint
to
the
3