Apogee Instruments SP-110 Owner's Manual - Page 11

Browse online or download pdf Owner's Manual for Measuring Instruments Apogee Instruments SP-110. Apogee Instruments SP-110 20 pages. Pyranometer
Also for Apogee Instruments SP-110: Owner's Manual (18 pages)

Apogee Instruments SP-110 Owner's Manual

OPERATION AND MEASUREMENT

Connect the sensor to a measurement device (meter, datalogger, controller) capable of measuring and displaying
or recording a millivolt (mV) signal (an input measurement range of approximately 0-250 mV is required to cover
the entire range of total shortwave radiation from the sun). In order to maximize measurement resolution and
signal-to-noise ratio, the input range of the measurement device should closely match the output range of the
pyranometer.
SP-110: The sensor is self-powered and applying voltage will damage the sensor.
VERY IMPORTANT:
Apogee changed the wiring colors of all our bare-lead sensors in March 2018 in
conjunction with the release of inline cable connectors on some sensors. To ensure proper connection to your
data device, please note your serial number or if your sensor has a stainless-steel connector 30 cm from the
sensor head then use the appropriate wiring configuration listed below. With the switch to connectors, we also
changed to using cables that only have 4 or 7 internal wires. To make our various sensors easier to connect to
your device, we clip off any unused wire colors at the end of the cable depending on the sensor. If you cut the
cable or modify the original pigtail, you may find wires inside that are not used with your particular sensor. In
this case, please disregard the extra wires and follow the color-coded wiring guide provided.
Wiring for SP-110 Serial Numbers 60051 and above or with a cable connector
Wiring for SP-110 Serial Numbers range 0-60050
Black: Negative (signal from sensor)
Clear: Shield/Ground
White: Positive (signal from sensor)
Red: Positive (signal from sensor)
Black: Negative (signal from sensor)
Clear: Shield/Ground